Functions:

  • Over-voltage protection
  • Under-voltage protection
  • Over-current protection
  • Automatic recovery
  • Voltage display(voltage measurement)
  • Current display (current measurement) 
  • Voltage calibration: Voltage +-10% adjustable. A13
  • Restore factory settings: press the down button for more than 12s
  • Fault inquiry: Press the UP button from more than 12S Product Parameters:
  • Model number:TOVPD1-60-EC
  • Power supply:230VAC 50/60Hz
  • Max.Loading power:1~40A
  • Adjustable(default:40A) 1~63A Adjustable(default:63A)
  • Over-voltage protection value range:230V~300~OFF
  • (default:270V) Over-voltage recovery voltage range:225V--295V(default:250V)
  • Over-voltage protection action time:0.1s~30s(default value:0.5s)
  • Over-voltage recovery delay time:1s~500s(default:30s)
  • Under-voltage protection value range:140V--210V --OFF
  • (default:170V) Under-voltage recovery voltage range:145V--215V
  • (default:190V) Under-voltage
  • protection action time:0.1s~30s(default:0.5s)
  • Under-voltage recovery delay time:1s~500s(default:30s)
  • Over-current adjustment range:1-40A (default:20A) 1-63A (default:40A) Over-current action range:0.1~30 second (default:0.5s) Over-currentrecovery delay time:1s~500s(default:30s)
  • Power-on delay time:1s~500s(default:10s) 9.Power consumption : <2W 10.Electric machinery life : 100,000 times 1
  • Installation:35mm DIN rail 110V Version
  • Power supply:110VAC 50/60Hz
  • Max.Loading power:1~63A Adjustable(default:63A)
  • Over-voltage protection value range:80V~300~OFF(default:145V)
  • Over-voltage recovery voltage range:75V--295V(default:140V)
  • Over-voltage protection action time:0.1s~30s(default value:0.5s)
  • Over-voltage r ecovery delay time:1s~500s(default:30s)
  • Under-voltage protection value range:80V--300V --OFF(default:90V)
  • Under-voltage recovery voltage range:85V--305V (default:95V)
  • Under-voltage protection action time:0.1s~30s(default:0.5s)
  • Under-voltage r ecovery delay time:1s~500s(default:30s)
  • Over-current adjustment range:1-63A (default:40A)
  • Over-current action range:0.1~30 second (default:0.5s)
  • Over-current r ecovery delay time:1s~500s(default:30s)
  • Power-on delay time:1s~500s(default:10s)
  • Power consumption : <2W 9.Electric machinery life : 100,000 times
  • Installation:35mm DIN rail